7.1.1.2 Image specifications
7.1.1.2.1 Response time
• Typical rise time: 6 ms
• Typical fall time: 6 ms
7.1.1.2.2 Tolerances
Tolerance test colors
The display unit complies with the following tolerances for the test colors specified in the EBU Tech
3325:
Maximal:
Typical:
In the table below, the Luminance Y is expressed in %. 100% is reference white.
Test color Description Y (%) u’ v’
EBU 1 Dark Skin 9.6
0
.
253 0
.5015
EBU 2 Light Skin 37.7
0
.
2366 0
.
4931
EBU 3 Light Greyish Red 29.8
0
.
2364 0
.
4848
EBU 4 Light Yellow Green
29
.
90
.
1807 0
.
5452
EBU 5 Light Bluish Green 29.8
0
.
1629 0
.
4552
EBU 6 Light Violet 30.1
0
.
2087 0
.
4157
EBU 7 Foliage
13
.
40
.
1813 0
.
5207
EBU 8 Medium Red 19.4
0
.
3248 0
.
4974
EBU 9 Medium Green
43
.
60
.
1505 0
.
5329
EBU 10 Medium Blue 17.2
0
.
1791 0
.
3706
0045.0'' vu