Table 15: Fault and warning list
The warnings under node “1” can easily be solved by the user. These warning are related to the
operation of the display unit out of the calibrated range. These warnings are considered as normal
153 W Saturation The saturation of window 2 is set to a value out of the cal-
ibrated range
154 W Hue The hue of window 2 is set to a value out of the calibrated
range
155 W RGB channels Not all color channels (R,G,B) are used for the output on
the screen for window 2
156 W Monochrome The output to the screen is set to monochrome for win-
dow 2
2 Licensing Node related to Faults and warnings related to the licens-
ing. More details can be found in the maintenance man-
ual.
3 Spectrometer Node related to spectrometer faults
301 F Spectrometer sta-
tus: Error
Hardware fault
302 F No spectrometer
found
Hardware fault
303 W Spectrometer re-
setting…
After error 301, the spectrometer will be resetting. In the
meantime, this error code is shown. When resetting is
not successful, error code 301 is displayed again.
4 Calibration data Node related to internal calibration faults
401 F Calibration data
error
Internal calibration data file is corrupt
402 F No calibration data
found
Internal calibration data file is not present
403 F Spectrometer data
error
Spectrometer data file is missing or corrupt