Tektronix 071-1143-01 Car Video System User Manual


 
Specifications
1-10
WFM90D and WFM91D Service Manual
Table 1- 10: Certifications and Compliances (Cont.)
Category Standards or description
Pollution Degree Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only.
Pollution Degree Descriptions A measure of the contaminates that could occur in the environment around and within a
product. Typically the internal environment inside a product is considered to be the same as the
external. Products should be used only in the environment for which they are rated.
Pollution Degree 1 No pollution or only dry, nonconductive pollution occurs. Products in this
category are generally encapsulated, hermetically sealed, or located in
clean rooms.
Pollution Degree 2 Normally only dry, nonconductive pollution occurs. Occasionally a
temporary conductivity that is caused by condensation must be expected.
This location is a typical office/home environment. Temporary condensation
occurs only when the product is out of service.
Pollution Degree 3 Conductive pollution, or dry, nonconductive pollution that becomes
conductive due to condensation. These are sheltered locations where
neither temperature nor humidity is controlled. The area is protected from
direct sunshine, rain, or direct wind.
Pollution Degree 4 Pollution that generates persistent conductivity through conductive dust,
rain, or snow. Typical outdoor locations.
1
Compliance demonstrated using high quality, shielded interface cables.
2
Minimum immunity test requirement, except where noted.
3
Performance Criterion: Product continues to operate properly and display remains readable.
4
Controlled EM environment requirement (1V/M).