Agilent Technologies E1446A Car Amplifier User Manual


 
*CLS
*CLS clears the Standard Event Status Register, the Operation Status Register, the
Questionable Signal Register, and the error queue. This clears the corresponding
summary bits (3, 5, & 7) in the Status Byte Register. *CLS does not affect the
enable masks of any of the status registers.
Comments
Executable when initiated: Yes
Coupling group: none
Related Commands: STATus:PRESet
*RST Condition: none
*DMC
*DMC <name>,<data> creates a macro with the specified name and assigns zero,
one, or a sequence of commands to the name. The sequence may be composed of
SCPI and/or Common Commands. The sequence must be sent in IEEE-488.2
definite or indefinite block format.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
name string
data
1 through 12 characters none
data block
data
or
string
any valid command
sequence
none
Comments
Legal macro names must start with an alphabetic character and contain only
alphabetic, numeric, and underscore ("_") characters. Alphabetic character case
(upper vs. lower) is ignored.
The name is allowed to be the same as a SCPI command, but may be not be the
same as a Common Command. When the name is the same as a SCPI command,
the macro rather than the command will be executed when the name is received if
macro usage is enabled. The SCPI command will be executed if macro usage is
disabled.
Executable when initiated: Yes
Coupling group: none
Related Commands: *EMC, *GMC, *LMC, *RMC
*CLS
3-26 Command Reference IEEE-488.2 Common Commands