Agilent Technologies E1446A Car Amplifier User Manual


 
Indefinite length block:
#0<data byte(s)><NL^END>
Examples of sending 4 data bytes:
#14<byte><byte><byte><byte>
#3004<byte><byte><byte><byte>
#0<byte><byte><byte><byte><NL^END>
Querying
Parameter Settings
Unless otherwise noted in the reference section, parameter settings can be
queried by adding a question mark (?) to the command which set the
parameter. For example:
INP:IMP 50
sets the impedance of the ’Input 1’ port to 50. The value can be queried by
executing:
INP:IMP?
The MINimum or MAXimum value of a parameter is determined as
follows:
INP:IMP? MIN
INP:IMP? MAX
SCPI Command Execution
The following information should be remembered when executing SCPI
commands.
Command Coupling The following amplifier commands are value coupled:
E1446 with E1405/06
OUTPut1:ATTenuation <attenuation>
OUTPut1:IMPedance <impedance>
SOURce:VOLTage[:LEVel][:IMMediate]:OFFSet <voltage>
E1446 with E1445
OUTPut2:ATTenuation <attenuation>
OUTPut2:IMPedance <impedance>
SOURce2:VOLTage[:LEVel][:IMMediate]:OFFSet <voltage>
SCPI Command Execution Command Reference 3-5