Program Execution The (new) amplifier configuration is set as shown in Figure C-4. The
execution sequence shown configures the amplifier from right-to-left
relative to Figure C-2.
Note Unlike other register-based devices, there is not a status bit which can
be monitored to determine when the amplifier registers can be written
to (WRITEIO). To allow the relays to close (or open), a 5 mS ’wait’
period (BASIC has 10 mS resolution) should be included following each
WRITEIO.