Issue 1 June 2005 1537
Translation Update Test (#146)
The Translation Update test sends the circuit pack-level information to the MAPD Interface
circuit pack. Translation includes the following data administered for a MAPD Interface circuit
pack (report from display ds1 location):
DS1 Link Length between two DS1 endpoints
Synchronization Source Control
All Zero Suppression
Framing Mode
Signaling Mode
Time Slot Number of the 697-Hz tone
Time Slot Number of the 700-Hz tone
Table 563: Test #146 Translation Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system software error.
1. Verify the MAPD Interface circuit pack translation (display ds1
location).
PASS Translation data has been downloaded to the MAPD Interface circuit
pack successfully.