A SERVICE OF

logo

Communication Manager Maintenance-Object Repair Procedures
932 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Possible reasons for a terminal not being downloaded include:
Terminal is off-hook.
Terminal detected a bad checksum.
Terminal detected a bad or missing EEPROM (refer to hardware error log).
Terminal is busy programming data from a previous PROGRAM message.
Terminal is in the Programming Disabled state.
Terminal is in the Local Program Options mode.
Terminal is disconnected or out of service (use status station).
Error Log Entries and Test to Clear Values
Table 319: Digital Line Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test port location sh r 1
1 (b
) (c) 40987
1 – 20
None WRN OFF
18 (d
)0 busyout port
location
WRN OFF release port location
130 (e
)None WRNONtest port location sh
257 (f
) 40971 None
513 0 Station (Digital)
Audits (#17)
WRN OFF test port location sh r 6
767 (g
) 40964 None WRN OFF
769 (h
)
(i
)
40963
40988
None WRN OFF
1026 (j
) NONE WRN OFF
1281 Any Station (Digital)
Audits (#17)
WRN OFF test port location sh r 4
1537 (k
) 40968 None WRN OFF
1 of 2