4.2.5 Interface unit parameter mode
The parameters whose abbreviations are marked* are made valid by changing the setting and then
switching power off once and switching it on again. Refer to Section 5.2.2.
The following example shows the operation procedure performed after power-on to change the serial
communication baudrate (IFU parameter No. 0) to 38400bps.
Using the "MODE" button, show the basic parameter screen.
The set value of the specified parameter number flickers.
UP DOWN
The parameter number is displayed.
Press or to change the number.
Press SET twice.
Press UP once.
During flickering, the set value can be changed.
Use or .
Press SET to enter.
( 2: Baudrate 38400bps)
UP DOWN
To shift to the next parameter, press the
UP DOWN
/
button.
When changing the parameter No. 0 setting, change its set value, then switch power off once and switch it