Mitsubishi Electronics MR-J3-T Car Amplifier User Manual


 
4 - 18
4. OPERATION
(2) Automatic continuous operation
(a) What is automatic continuous operation?
By merely choosing one point table and making a start (ST1 or ST2), operation can be performed in
accordance with the point tables having consecutive numbers.
Automatic operation is available in two types. varied speed operation and automatic continuous
positioning operation.
Either type may be selected as follows.
1) In absolute value command specifying system
Point table setting
Dwell
Auxiliary function
A
utomatic continuous
operation
Speed changing operation
Automatic continuous
positioning operation
When position data is
absolute value
When position data is
incremental value
0 1 3
1 or more 1 3
2) In incremental value command system
A
utomatic continuous
operation
Speed changing operation
Automatic continuous
positioning operation
Point table setting
Dwell Auxiliary function
0 1
1 or more 1
(b) Varied speed operation
By setting "1" to the auxiliary function of up to point table No.254, operation can be performed at a
maximum of 255 speeds. Set "0" to the auxiliary function of the last point table.
When performing varied speed operation, always set "0" to the dwell. If "1" or more is set, automatic
continuous positioning operation is made valid.
The following table gives a setting example.
Point table No. Dwell [ms] (Note 1) Auxiliary function Variable speed operation
1 0 1
Consecutive point table data
2 0 1
3 0 0 (Note 2)
4 0 1
Consecutive point table data
5 0 1
6 0 1
7 0 0 (Note 2)
Note 1. Always set "0".
2. Always set "0" or "2" to the auxiliary function of the last point table among the consecutive point tables.