4 - 63
4. OPERATION
(b) For MR-J3-500T or more and MR-J3-350T4 or more
Insert connector into CN4.
(c) Parameter setting
Set parameter No.PA03 (Absolute position detection system) as indicated below to make the absolute
position detection system valid.
Parameter No.PA03
Selection of absolute position detection system
0: Incremental system
1: Absolute position detection system
1