Mitsubishi Electronics MR-J2S- A Car Amplifier User Manual


 
5 - 14
5. PARAMETERS
Class No. Symbol Name and function
Initial
value
Unit
Setting
range
Control
mode
21 *OP3 Function selection 3 (Command pulse selection)
Used to select the input form of the pulse train input signal.
(Refer to section 3.4.1)
Command pulse train input form
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A B-phase pulse train
Pulse train logic selection
0: Positive logic
1: Negative logic
00
0000 Refer to
Name
and
function
column.
P
22 *OP4 0000
P S
Expansion parameters 1
Function selection 4
Used to select stop processing at forward rotation stroke end (LSP)
reverse rotation stroke end (LSN)
off and choose VC/VLA voltage
averaging.
How to make a stop when forward
rotation stroke end (LSP) reverse rotation stroke end
(LSN) is valid. (Refer to section 5.2.3)
0: Sudden stop
1: Slow stop
VC/VLA voltage averaging
Used to set the filtering time when the analog speed
command (VC) voltage or analog speed limit (VLA) is
imported.
Set 0 to vary the speed to voltage fluctuation in real
time. Increase the set value to vary the speed slower
to voltage fluctuation.
Set
value
0
Filtering time [ms]
0
10.444
20.888
31.777
43.555
00
Refer to
Name
and
function
column.
P S T