Mitsubishi Electronics MR-J2S- A Car Amplifier User Manual


 
1 - 24
1. FUNCTIONS AND CONFIGURATION
(5) MR-J2S-11KA or more
(Note 1)
L
11
L
21
L
2
L1
L
3
MITS UBIS HI
UVW
BV
BU
C
P
To CN1A
To CN1B
(Note 3)
Power supply
No-fuse
breaker
(NFB) or
fuse
Magnetic
contactor
(MC)
Power
factor
improving
reactor
(FA-BAL)
Regenerative
option
Command device
Junction terminal
block
Personal
computer
MR Configurator
(Servo
configuration
software
MRZJW3-
SETUP151E)
(Note 2)
Power factor
improving DC reactor
(FR-BEL)
To CN4
To CN2
BW
(Note 2)
Analog monitor
Servo motor
series
To CN3
Options and auxiliary equipment Reference
No-fuse breaker
Magnetic contactor
MR Configurator
(Servo configuration software)
Section 13.2.2
Section 13.2.2
Section 13.1.9
Options and auxiliary equipment Reference
Regenerative option
Cables
Power factor improving reactor
Section 13.1.1
Section 13.2.1
Section 13.2.3
Power factor improving
DC reactor
Section 13.2.4
Note 1. Cooling fan power supply of the HA-LFS11K2 servo motor is 1-phase. Power supply specification of the cooling fan is different
from that of the servo amplifier. Therefore, separate power supply is required.
2. Use either the FR-BAL or FR-BEL power factor improving reactor.
3. Refer to section 1.3 for the power supply specification.