13 - 47
13. OPTIONS AND AUXILIARY EQUIPMENT
13.2.2 No-fuse breakers, fuses, magnetic contactors
Always use one no-fuse breaker and one magnetic contactor with one servo amplifier. When using a fuse
instead of the no-fuse breaker, use the one having the specifications given in this section.
Fuse
Servo amplifier No-fuse breaker
Class Current[A] Voltage AC [V]
Magnetic contactor
MR-J2S-10A(1) 30A frame 5A K5 10
MR-J2S-20A 30A frame 5A K5 10
MR-J2S-40A 20A1 30A frame 10A K5 15
MR-J2S-60A 40A1 30A frame 15A K5 20
MR-J2S-70A 30A frame 15A K5 20
MR-J2S-100A 30A frame 15A K5 25
S-N10
MR-J2S-200A 30A frame 20A K5 40 250 S-N18
MR-J2S-350A 30A frame 30A K5 70 S-N20
MR-J2S-500A 50A frame 50A K5 125 S-N35
MR-J2S-700A 100A frame 75A K5 150 S-N50
MR-J2S-11KA 100A frame 100A K5 200 S-N65
MR-J2S-15KA 225A frame 125A K5 250 S-N95
MR-J2S-22KA 225A frame 175A K5 350 S-N25
13.2.3 Power factor improving reactors
The input power factor is improved to be about 90%. For use with a 1-phase power supply, it may be
slightly lower than 90%.
3-phase
200 to 230VAC
NFB
FR-BAL
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
1-phase
230VAC
NFB
FR-BAL
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
1-phase
100 to120VAC
NFB
FR-BAL
R
S
T
X
Y
Z
L
1
L
2
MC
W
W1C
RXSYTZ
H 5
D1
Installation screw
D 5
[Unit : mm]
(Note)
Servo amplifier
MR-J2S- A
Servo amplifier
MR-J2S- A
Servo amplifier
MR-J2S- A1
Note. For the 1-phase 230V power supply, Connect the power supply to L1, L2 and leave L3 open.
Dimensions [mm (in) ]
Servo amplifier Model
WW1H D D1 C
Mounting
screw size
Terminal
screw size
Mass
[kg (lb)]
MR-J2S-10A(1)/20A FR-BAL-0.4K 135 (5.31) 120 (4.72) 115 (4.53) 59 (2.32)
45
0
-2.5
(1.77
0
-0.098
)
7.5 (0.29) M4 M3.5 2.0 (4.4)
MR-J2S-40A/20A1 FR-BAL-0.75K 135 (5.31) 120 (4.72) 115 (4.53) 69 (2.72)
57
0
-2.5
(2.24
0
-0.098
)
7.5 (0.29) M4 M3.5 2.8 (6.17)
MR-J2S-60A/70A/40A1 FR-BAL-1.5K 160 (6.30) 145 (5.71) 140 (5.51) 71 (2.79)
55
0
-2.5
(2.17
0
-0.098
)
7.5 (0.29) M4 M3.5 3.7 (8.16)
MR-J2S-100A FR-BAL-2.2K 160 (6.30) 145 (5.71) 140 (5.51) 91 (3.58)
75
0
-2.5
(2.95
0
-0.098
)
7.5 (0.29) M4 M3.5 5.6 (12.35)
MR-J2S-200A FR-BAL-3.7K 220 (8.66) 200 (7.87) 192 (7.56) 90 (3.54)
70
0
-2.5
(2.76
0
-0.098
)
10 (0.39) M5 M4 8.5 (18.74)
MR-J2S-350A FR-BAL-7.5K 220 (8.66) 200 (7.87) 194 (7.64) 120 (4.72)
100
0
-2.5
(3.94
0
-0.098
)
10 (0.39) M5 M5 14.5 (32.0)
MR-J2S-500A FR-BAL-11K 280 (11.02) 255 (10.04) 220 (8.66) 135 (5.31)
100
0
-2.5
(3.94
0
-0.098
)
12.5 (0.49) M6 M6 19 (41.9)
MR-J2S-700A/11KA FR-BAL-15K 295 (11.61) 270 (10.62) 275 (10.83) 133 (5.24)
110
0
-2.5
(4.33
0
-0.098
)
12.5 (0.49) M6 M6 27 (59.5)
MR-J2S-15KA FR-BAL-22K 290 (11.41) 240 (9.75) 301 (11.85) 199 (7.84) 170 5 (6.69 0.2) 25 (0.98) M8 M8 35 (77.16)