Furuno MR-J2S-A Car Amplifier User Manual


 
15 - 15
15. ABSOLUTE POSITION DETECTION SYSTEM
(4) At the time of emergency stop reset
(a) If the power is switched ON in the emergency stop state
The emergency stop state can be reset while the ABS data is being transferred.
If the emergency stop state is reset while the ABS data is transmitted, the base circuit is turned
ON 80[ms] after resetting. If the ABS transfer mode signal (ABSM) is OFF when the base circuit is
turned ON, the ready signal (RD) is turned ON 20[ms] after the turning ON of the base circuit. If
the ABS transfer mode signal (ABSM) is ON when the base circuit is turned ON, it is turned OFF
and then the ready signal (RD) is turned ON. The ABS data can be transmitted after the
emergency stop state is reset.
The current position in the servo amplifier is updated even during an emergency stop. When servo-
on (SON) and ABS transfer mode (ABSM) are turned ON during an emergency stop as shown
below, the servo amplifier transmits to the controller the current position latched when the ABS
transfer mode (ABSM) switches from OFF to ON, and at the same time, the servo amplifier sets
this data as a position command value. However, since the base circuit is OFF during an
emergency stop, the servo-lock status is not encountered. Therefore, if the servo motor is rotated by
external force or the like after the ABS transfer mode (ABSM) is turned ON, this travel is
accumulated in the servo amplifier as droop pulses. If the emergency stop is cleared in this status,
the base circuit turns ON and the motor returns to the original position rapidly to compensate for
the droop pulses. To avoid this status, reread the ABS data before clearing the emergency stop.
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
80[ms]
OFF
ON
20[ms]
Power
supply
Servo-on
(SON)
Emergency stop
(EMG)
A
BS transfer mode
(ABSM)
A
BS request
(ABSR)
Send data ready
(TLC)
Send (ABS) data
Base circuit
Ready
(RD)
Reset
During transfer of ABS
ABS data
Operation
enabled