Furuno MR-J2S-A Car Amplifier User Manual


 
3 - 15
3. SIGNALS AND WIRING
Control
mode
Signal Symbol
Connec-
tor pin
No.
Functions/Applications
I/O
division
PST
Outside torque
limit selection
TL CN1B
9
Torque limit selection disconnecting TL-SG makes internal torque
limit 1 (parameter No. 28) valid and connecting them makes
analog torque limit (TLA) valid.
For details, refer to (5), Section 3.4.1.
DI-1
Internal
torque limit
selection
TL1 When using this signal, make it usable by making the setting of
parameter No. 43 to 48.
For details, refer to (5), Section 3.4.1.
DI-1
Used to start the servo motor in any of the following directions:
(Note) Input signals
ST2 ST1
Servo motor starting direction
Forward rotation
start
ST1 CN1B
8
0 0 Stop (servo lock)
01 CCW
10 CW
1 1 Stop (servo lock)
Reverse rotation
start
ST2 CN1B
9
Note. 0: ST1/ST2-SG off (open)
1: ST1/ST2-SG on (short)
If both ST1 and ST2 are switched on or off during operation, the
servo motor will be decelerated to a stop according to the
parameter No. 12 setting and servo-locked.
DI-1
Used to select any of the following servo motor torque generation
directions:
(Note) Input signals
RS2 RS1
Torque generation direction
Forward rotation
selection
RS1 CN1B
9
0 0 Torque is not generated.
01
Forward rotation in driving mode /
reverse rotation in regenerative mode
10
Reverse rotation in driving mode /
forward rotation in regenerative mode
1 1 Torque is not generated.
Reverse rotation
selection
RS2 CN1B
8
Note. 0: RS1/RS2-SG off (open)
1: RS1/RS2-SG on (short)
DI-1