Mitsumi electronic mr-j3-b Car Amplifier User Manual


 
5. PARAMETERS
5 - 10
5.2 Detailed list of parameters
POINT
Set a value in each "x" in the "Setting digit" columns.
5.2.1 Basic setting parameters ([Pr. PA_ _ ])
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PA02 **REG Regenerative option
Select a regenerative option.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 37 Parameter
error] occurs.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ x x Regenerative option selection
00: No regenerative option is used.
For a servo amplifier of 200 W or less, no regenerative
resistor is used.
For a servo amplifier of 0.4 kW to 3 kW, a built-in
regenerative resistor is used.
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (A cooling fan is required.)
00h
_ x _ _ For manufacturer setting 0h
x _ _ _ 0h
PA03 *ABS Absolute position detection system
Set this parameter when using the absolute position detection system.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Absolute position detection system selection
0: Disabled (used in the incremental system)
1: Enabled (used in the absolute position detection system)
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h