5. PARAMETERS
5 - 22
No. Symbol Name and function
Initial
value
[Unit]
Setting
range
PB19 VRF11 Vibration suppression control 1 - Vibration frequency
Set the vibration frequency for the vibration suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)"
in [Pr. PB02], this parameter will be set automatically. Set this parameter manually when
"Manual setting (_ _ _ 2)" is selected. Refer to section 7.1.5 for details.
100.0
[Hz]
0.1
to
300.0
PB20 VRF12 Vibration suppression control 1 - Resonance frequency
Set the resonance frequency for the vibration suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)"
in [Pr. PB02], this parameter will be set automatically. Set this parameter manually for "Manual
setting (_ _ _ 2)". Refer to section 7.1.5 for details.
100.0
[Hz]
0.1
to
300.0
PB21 VRF13 Vibration suppression control 1 - Vibration frequency damping
Set a damping of the vibration frequency for the vibration suppression control 1 to suppress
low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)"
in [Pr. PB02], this parameter will be set automatically. Set this parameter manually for "Manual
setting (_ _ _ 2)". Refer to section 7.1.5 for details.
0.00 0.00
to
0.30
PB22 VRF14 Vibration suppression control 1 - Resonance frequency damping
Set a damping of the resonance frequency for the vibration suppression control 1 to suppress
low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)"
in [Pr. PB02], this parameter will be set automatically. Set this parameter manually for "Manual
setting (_ _ _ 2)". Refer to section 7.1.5 for details.
0.00 0.00
to
0.30
PB23 VFBF Low-pass filter selection
Select the shaft resonance suppression filter and low-pass filter.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Shaft resonance suppression filter selection
0: Automatic setting
1: Manual setting
2: Disabled
When you select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 4 selection" in [Pr. PB49], the shaft resonance
suppression filter cannot be used.
0h
_ _ x _ Low-pass filter selection
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _ For manufacturer setting 0h
x _ _ _ 0h