Mitsumi electronic mr-j3-b Car Amplifier User Manual


 
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 41
(d) Line noise filter (FR-BSF01)
This filter is effective in suppressing noises radiated from the power supply side and output side of
the servo amplifier and also in suppressing high-frequency leakage current (0-phase current). It
especially affects the noises between 0.5 MHz and 5 MHz band.
Connection diagram Dimensions [Unit: mm]
The line noise filters can be installed on lines of the power supply
(L1, L2, and L3) and of the servo motor power (U, V, and W).
Pass each of the wires through the line noise filter an equal
number of times in the same direction. For the power supply, the
effect of the filter rises as the number of passes increases, but
generally four passes would be appropriate. For the servo motor
power lines, passes must be four times or less. Do not pass the
grounding wire through the filter. Or the effect of the filter will drop.
Wind the wires by passing through the filter to satisfy the required
number of passes as shown in Example 1. If the wires are too
thick to wind, use two or more filters to have the required number
of passes as shown in Example 2.
Place the line noise filters as close to the servo amplifier as
possible for their best performance.
MCMCCB
Example 1
Power
supply
Power
supply
Servo amplifier
Line noise
filter
L1
L2
L3
(Number of passes: 4)
MCMCCB
Line noise
filter
Example 2
Servo amplifie
r
L1
L2
L3
Two filters are used
(Total number of passes: 4)
FR-BSF01 (for wire size 3.5 mm
2
(AWG 12) or smaller)
φ
33
4.5
Approx. 110
95 ± 0.5
Approx. 22.5
Approx. 65
Approx. 65
2-
φ
5
11.25± 0.5