Mitsumi electronic mr-j3-b Car Amplifier User Manual


 
5. PARAMETERS
5 - 17
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PA25 OTHOV One-touch tuning - Overshoot permissible level
Set a permissible value of the overshoot amount for one-touch tuning as a percentage of the
in-position range.
However, setting "0" will be 50%.
0
[%]
0 to 100
PA26 *AOP5 Function selection A-5 Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Torque limit function selection at instantaneous power failure
(instantaneous power failure tough drive selection)
0: Disabled
1: Enabled
When an instantaneous power failure occurs during operation, you
can save electric energy charged in the capacitor in the servo
amplifier by limiting torque at acceleration. You can also delay the
time until the occurrence of [AL. 10.2 Bus voltage drop] with the
instantaneous power failure tough drive function. Doing this will
enable you to set a longer time in [Pr. PF25 Instantaneous power
failure tough drive - Detection time].
The torque limit function at instantaneous power failure is enabled
when "instantaneous power failure tough drive selection" in [Pr.
PA20] is "Enabled (_ 1 _ _)".
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h
PA27 *HTL Hot line forced stop function Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Hot line forced stop function selection
0: Enabled
1: Disabled
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h