Mitsumi electronic mr-j3-b Car Amplifier User Manual


 
5. PARAMETERS
5 - 14
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PA19 *BLK Parameter writing inhibit
Select a reference range and writing range of parameters.
Refer to table 5.3 for settings.
00AAh Refer to
the
"Name
and
function"
column.
Table 5.3 [Pr. PA19] setting value and reading/writing range
PA19
Setting
operation
PA PB PC PD PE PF
Other than
below
Reading
Writing
000Ah
Reading Only 19
Writing Only 19
000Bh
Reading
Writing
000Ch
Reading
Writing
000Fh
Reading
Writing
00AAh
(initial
value)
Reading
Writing
100Bh
Reading
Writing Only 19
100Ch
Reading
Writing Only 19
100Fh
Reading
Writing Only 19
10AAh
Reading
Writing Only 19