Mitsumi electronic mr-j3-b Car Amplifier User Manual


 
5. PARAMETERS
5 - 35
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PD14 *DOP3 Function selection D-3 Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x For manufacturer setting 0h
_ _ x _ Selection of output device at warning occurrence
Select the WNG (Warning) and ALM (Malfunction) output status at
warning occurrence.
Servo amplifier output
0h
Setting
value
(Note 1) Device status
0
0
1
0
1
W
NG
A
LM
Warning occurrence
1
0
1
0
1
WNG
A
LM
Warning occurrence (Note 2)
Note 1. 0: Off
1: On
2.
A
lthough ALM is turned off upon occurrence of the
warning, the forced stop deceleration is performed.
_ x _ _ For manufacturer setting 0h
x _ _ _ 0h