Mitsumi electronic mr-j3-b Car Amplifier User Manual


 
3. SIGNALS AND WIRING
3 - 3
(1) For 3-phase 200 V AC to 240 V AC power supply of MR-JE-10B to MR-JE-100B
POINT
For MR-JE-_B servo amplifiers, the hot line forced stop function is enabled at
factory setting. For MR-J4-_B servo amplifiers, the hot line forced stop function
is disabled at factory setting.
If an alarm occurs, the hot line forced stop function outputs hot line forced stop
signals to all servo amplifiers before a communication to the controller is cut.
Then, servo amplifiers will be in the [AL. E7.1 Controller forced stop warning]
state and will decelerate to a stop.
The hot line forced stop function can be disabled with [Pr. PA27].
Configure the power supply circuit which turns off magnetic contactors of all
servo amplifiers after detection of alarm occurrence on the controller side at
alarm occurrence.
MC (Note 8)
MBR
DOCOM
CN3
(Note 3)
24 V DC (Note 9)
24 V DC (Note 9)
Electromagnetic
brake interlock
RA1
L1
L2
L3
3-phase
200 V AC to
240 V AC
Servo amplifier
U
V
W
(Note 1)
CNP1
Servo motor
U
V
W
M
Motor
Encoder
CN2
(Note 2)
Encoder cable
(Note 4, 7)
CN3
Forced stop 2
(Note 3)
EM2
DICOM
(Note 6)
Power
supply
MCCB
(Note 7)
C
P+
Built-in
regenerative
resistor
(Note 5)
Alarm
OFF
MC
ON
MC
SK
EMG stop switch