Mitsumi electronic mr-j3-b Car Amplifier User Manual


 
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 46
(c) For 1-phase 200 V AC to 240 V AC power supply of MR-JE-200B
MCCB
Servo amplifie
r
1
2
3
(Note 2)
Surge protector
(RSPD-250-U4)
(OKAYA Electric Industries Co., Ltd.)
(Note 1)
1-phase
200 VAC to 240 V AC
123
MC
EMC filter
L1
L2
L3
4
5
6
E
Note 1. Connect the power supply to L1 and L3. Leave L2 open.
2. The example is when a surge protector is connected.
(3) Dimensions
(a) EMC filter
HF3010A-UN
[Unit: mm]
32 ± 2
85 ± 2
110 ± 4
258 ± 4
273 ± 2
288 ± 4
300 ± 5
M4
IN
3-M4
65 ± 4
Approx. 41
4-5.5 × 73-M4
HF3030A-UN
[Unit: mm]
125 ± 2
44 ± 1
260 ± 5
140 ± 2
70 ± 2
140 ± 1
155 ± 2
3-M5
6-R3.25 length:8
3-M5
M4
85 ± 1
210 ± 2
85 ± 1