App. 8 When using the hot line forced stop function in combination with MR-J4-_B servo
amplifier
At factory setting, MR-J4-_B servo amplifiers do not decelerate to a stop by the hot line forced stop function
if an alarm occurs in an MR-JE-_B servo amplifier.
To decelerate MR-J4-_B servo amplifiers to a stop by the hot line forced stop function, enable the
deceleration to a stop selection with [Pr. PA27].
If an alarm occurs in the MR-J4-_B servo amplifier, MR-JE-_B and MR-J4-_B servo amplifiers do not
decelerate to a stop by the hot line forced stop function.
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PA27 *HTL Hot line forced stop function Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Deceleration to a stop selection
Select enabled/disabled of deceleration to a stop for when a hot line
forced stop signal is received.
0: Disabled
2: Enabled
This parameter is used by servo amplifier with software version B6
or later.
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h