Mitsubishi Electronics MR-J2S- CP Car Amplifier User Manual


 
4 - 24
4. OPERATION
4.3.2 Manual pulse generator operation
(1) Setting
Set the input signal and parameters as follows according to the purpose of use. In this case, the point
table No. selection 1 to 5 (DI0 to DI4) are invalid.
Item Setting method Description
Manual operation mode selection Automatic/manual selection (MD0) Open MD0-SG (OFF).
Manual pulse generator
multiplication
Parameter No.1
Set the multiplication ratio of servo
motor rotation to the pulses generated by
the manual pulse generator.
For more information, refer to (3) of this
section.
Servo motor rotation direction Parameter No.1 Refer to (2) of this section.
(2) Servo motor rotation direction
Servo motor rotation direction
Parameter No. 1 setting
Manual pulse generator: forward rotation Manual pulse generator: reverse rotation
0 CCW rotation CW rotation
1 CW rotation CCW rotation
Forward rotation
CCW
CW
(3) Manual pulse generator multiplication
(a) Using the parameter for setting
Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No. 1 setting
Multiplication ratio of servo motor rotation to manual
pulse generator rotation
Moving distance
0 1 time 1[ m]
1 10 times 10[ m]
2 100 times 100[ m]