7 - 2
7. DISPLAY AND OPERATION
7.2 Status display
The servo status during operation is shown on the 5-digit, 7-segment LED display. Press the "UP" or
"DOWN" button to change display data as desired. When the required data is selected, the corresponding
symbol appears. Press the "SET" button to display its data. At only power-on, however, data appears after
the symbol of the status display selected in parameter No. 18 has been shown for 2[s].
The servo amplifier display shows the lower five digits of 16 data items such as the motor speed.
7.2.1 Display transition
After choosing the status display mode with the "MODE" button, pressing the "UP" or "DOWN" button
changes the display as shown below.
Current position
Command position
Command remaining
distance
Point table No.
Cumulative feedback
pulses
Servo motor speed
Droop pulses
Override
Analog torque
limit voltage
Regenerative load ratio
Effective load ratio
Peak load ratio
Instantaneous torque
Within one-revolution
position low
Within one-revolution
position high
ABS counter
Load inertia moment ratio
Bus voltage
To Bus voltage
To Current position
UP
DOWN