Mitsubishi Electronics MR-J2S- CP Car Amplifier User Manual


 
4 - 25
4. OPERATION
(b) Using the input signals for setting
Set the pulse generator multiplication 1 (TP0) and pulse generator multiplication 2 (TP1) to the
input signals in "Device setting" on the MR Configurator (servo configuration software) (refer to
chapter 6).
(Note) Pulse generator
multiplication 2
(across TP1)
(Note) Pulse generator
multiplication 1
(across TP0)
Multiplication ratio of servo motor
rotation to manual pulse generator
rotation
Moving distance
0 0 Parameter No.1 setting valid
0 1 1 time 1[ m]
1 0 10 times 10[ m]
1 1 100 times 100[ m]
Note. 0: Open across TP1/TP0-SG
1: Shorted across TP1/TP0-SG
(4) Operation
Turn the manual pulse generator to rotate the servo motor. For the rotation direction of servo motor,
refer to (2) of this section.