6 - 29
6. PARAMETERS
6.4 I/O setting parameters (No.PD
)
6.4.1 Parameter list
No. Symbol Name Initial value Unit
PD01 *DIA1 Input signal automatic ON selection 1 0000h
PD02 For manufacturer setting 0000h
PD03 *DIA3 Input signal automatic ON selection 3 0000h
PD04 *DIA4 Input signal automatic ON selection 4 0000h
PD05 For manufacturer setting 0000h
PD06 *DI2 Input signal device selection 2 (CN6-2) 002Bh
PD07 *DI3 Input signal device selection 3 (CN6-3) 000Ah
PD08 *DI4 Input signal device selection 4 (CN6-4) 000Bh
PD09 *DO1 Output signal device selection 1 (CN6-14) 0002h
PD10 *DO2 Output signal device selection 2 (CN6-15) 0003h
PD11 *DO3 Output signal device selection 3 (CN6-16) 0024h
PD12 DIN1 External DI function selection 1 0C00h
PD13 For manufacturer setting 0000h
PD14 DIN3 External DI function selection 3 0800h
PD15 For manufacturer setting 0000h
PD16 *DIAB Input polarity selection 0000h
PD17 0000h
PD18
For manufacturer setting
0000h
PD19 *DIF Response level setting 0002h
PD20 *DOP1 Function selection D-1 0010h
PD21 For manufacturer setting 0000h
PD22 *DOP3 Function selection D-3 0000h
PD23 For manufacturer setting 0000h
PD24 *DOP5 Function selection D-5 0000h
PD25 0000h
PD26 0000h
PD27 0000h
PD28 0000h
PD29 0000h
PD30
For manufacturer setting
0000h