3 - 6
3. CC-LINK COMMUNICATION FUNCTIONS
3.2.4 Communication baud rate setting
Set the transfer baud rate of CC-Link with the transfer baud rate switch (MODE) on the servo amplifier front.
The initial value is set to 156kbps.
The overall distance of the system changes with the transfer speed setting. For details, refer to the CC-Link
system master/local unit user's manual.
MODE
5
4
3
2
1
0
9
8
7
6
5
0
5
0
5
0
Servo amplifier
No.
Baud rate
156kbps
1
2
3
4
5 to 9
625kbps
2.5Mbps
5Mbps
10Mbps
Not used
0 (initial value)
3.2.5 Occupied station count setting
Set the number of occupied stations with the occupied station count switch (SW1) on the servo amplifier front.
The usable I/O device and the number of connectable units change with the set number of occupied stations.
Refer to section 3.2.3. In the initial status, the number of stations occupied is set to 1.
5
0
5
0
5
0
Servo amplifier
(Note)
SW1 setting Number of occupied stations
Initial value
1 station occupied
2 station occupied
This switch hidden under the cover is for manufacturer setting.
Do not change this setting by any means.
SW1
Note.