Mitsubishi Electronics MR-J3- T Car Amplifier User Manual


 
11 - 10
11. TROUBLESHOOTING
Display Name Definition Cause Action
A52 Error excessive 1. Acceleration/deceleration time
constant is too small.
Increase the acceleration/deceleration time
constant.
2. Forward rotation torque limit
(parameter No.PA11) or reverse
rotation torque limit (parameter
No.PA12) are too small.
Increase the torque limit value.
The difference
between the model
position and the
actual servo motor
position exceeds
three rotations.
(Refer to the function
block diagram in
section 1.1.2.)
3. Motor cannot be started due to
torque shortage caused by power
supply voltage drop.
1. Check the power supply capacity.
2. Use servo motor which provides larger
output.
4. Position loop gain (parameter
No.PB08) value is small.
Increase set value and adjust to ensure
proper operation.
5. Servo motor shaft was rotated by
external force.
1. When torque is limited, increase the limit
value.
2. Reduce load.
3. Use servo motor that provides larger
output.
6. Machine struck something. 1. Check operation pattern.
2. Install limit switches.
7. Encoder faulty. Change the servo motor.
8. Wrong connection of servo motor.
Servo amplifier’s output terminals U,
V, W do not match servo motor’s
input terminals U, V, W.
Connect correctly.
A61 Operation alarm Setting mistake of
auxiliary function.
"1" or "3" is set for the auxiliary
function of point table No.255.
Set "0" or "2" for the value of auxiliary
function.
A8A 1. Communication cable breakage. Repair or change the communication cable.
2. Communication cycle longer than
regulated time.
Shorten the communication cycle.
Serial
communication
time-out error
Communication
stopped for longer
than the specified
time.
3. Wrong protocol. Correct protocol.
A8D CC-Link alarm 1. The station number switch
(STATION NO.) setting is 0 or not
less than 65.
Set the station number to within the range 1
to 64, and switch power on.
Normal
communication with
the master station
cannot be made.
2. The baud rate switch (MODE)
setting is outside the range 0 to 4.
Set the baud rate switch (MODE) to within
the range 0 to 4.
3. The transmission status is
abnormal.
Reexamine the wiring.
4. CC-Link twisted cable wiring
incorrect.
5. CC-Link twisted cable faulty.
1. Repair or change the CC-Link twisted
cable.
2. Connect the cable or connector correctly.
6. The CC-Link connector has come
off.
7. The terminating resistor is not
connected.
Connect the terminating resistor correctly.
8. Noise entered the CC-Link twisted
cable.
9. The programmable controller CC-
Link unit was reset.
1. Communication cable fault
(Open cable or short circuit).
Repair or change the cable. A8E Serial
communication
error
Serial communication
error occurred
between servo
amplifier and
communication
device (e.g. personal
computer).
2. Communication device (e.g.
personal computer) faulty.
Change the communication device (e.g.
personal computer).