16 - 35
16. INDEXER POSITIONING OPERATION
16.5.5 Point table setting
Set necessary items to the point table before starting operation. The following table indicates the items that
must be set.
Name Description
Position data
Not used in indexer positioning operation.
Do not change this value by any means.
Servo motor speed Set the command speed of the servo motor for execution of positioning.
Acceleration time constant Set the acceleration time constant.
Deceleration time constant Set the deceleration time constant.
Dwell
Not used in indexer positioning operation.
Do not change this value by any means.
Auxiliary function
Not used in indexer positioning operation.
Do not change this value by any means.
16.5.6 Actual operation
Start actual operation after confirmation of normal operation by test operation and completion of the
corresponding parameter settings. Perform a home position return as necessary.