No. Symbol Name and function Initial value Unit Setting range
PC46 *STN Indexer positioning operation number of stations/rotation
Set the number of stations (dividing number) per machine rotation. When
the setting value is 2 or lower, the number of stations is set to 2.
0000h Number of
stations
0000h
to
00FFh
Setting value
Number of
stations
0000 2
0001 2
0002 2
0003 3
0004 4
00FF 255
PC47 PSST Indexer positioning operation station home position shift distance
This parameter is available only in the absolute position detection system.
Set the distance for shifting the home position toward the set home
position in number of pulses.
This shift distance does not become valid immediately after the home
position setting. It becomes valid after turning off and then on the power.
When the sift distance is larger than the in-position range, the in position
(RXn1) does not turn on at power-on.
Set the number of pulses to be shifted after converting it into hexadecimal.
The setting range is from
2000 to 2000 pulse.
0000h pulse Refer to
name and
function
column
PC48 For manufacturer setting 0000h
PC49 Do not change this value by any means. 0000h
PC50
0000h
(3) Alarm history clear
The alarm history can be confirmed by using the MR Configurator. The servo amplifier stores one current
alarm and five past alarms from when its power is switched on first. To control alarms which will occur
during operation, clear the alarm history using parameter No.PC18 (alarm history clear) before starting
operation. Clearing the alarm history automatically returns to "
0".
This parameter is made valid by switching power off, then on after setting.
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleared)
Parameter No.16