14 - 19
14. OPTIONS AND AUXILIARY EQUIPMENT
14.2 Regenerative options
CAUTION
The specified combinations of regenerative options and servo amplifiers may only
be used. Otherwise, a fire may occur.
(1) Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Regenerative power[W]
Servo amplifier
Built-in
regenerative
resistor
MR-RB032
[40
]
MR-RB12
[40 ]
MR-RB30
[13 ]
MR-RB31
[6.7 ]
MR-RB32
[40 ]
(Note 1)
MR-RB50
[13
]
(Note 1)
MR-MB51
[6.7
]
MR-J3-10T (1) 30
MR-J3-20T (1) 10 30 100
MR-J3-40T (1) 10 30 100
MR-J3-60T 10 30 100
MR-J3-70T 20 30 100 300
MR-J3-100T 20 30 100 300
MR-J3-200T 100 300 500
MR-J3-350T 100 300 500
MR-J3-500T 130 300 500
MR-J3-700T 170 300 500
Regenerative power[W]
Servo amplifier
Built-in
regenerative
resistor
MR-RB1H-4
[82
]
(Note 1)
MR-RB3M-4
[120
]
(Note 1)
MR-RB3G-4
[47
]
(Note 1)
MR-RB5G-4
[47
]
(Note 1)
MR-RB34-4
[26
]
(Note 1)
MR-RB54-4
[26
]
MR-J3-60T4 15 100 300
MR-J3-100T4 15 100 300
MR-J3-200T4 100 300 500
MR-J3-350T4 100 300 500
MR-J3-500T4 130 300 500
MR-J3-700T4 170 300 500
(Note 2) Regenerative power[W]
Servo amplifier
External regenerative
resistor (Accessory)
MR-RB5E
[6
]
MR-RB9P
[4.5 ]
MR-RB9F
[3 ]
MR-RB6B-4
[20 ]
MR-RB60-4
[12.5 ]
MR-RB6K-4
[10 ]
MR-J3-11KT 500 (800) 500 (800)
MR-J3-15KT 850 (1300) 850 (1300)
MR-J3-22KT 850 (1300) 850 (1300)
MR-J3-11KT4 500 (800) 500 (800)
MR-J3-15KT4 850 (1300) 850 (1300)
MR-J3-22KT4 850 (1300) 850 (1300)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.