App. - 17
A
PPENDI
X
(2) Reading the parameter
Read parameter No.PA04 "Function selection A-1" of the servo amplifier of station 2 to D1.
Data No. Description
H8200 Parameter group selection
H2024 Parameter No.PA04 setting (hexadecimal)
Read the parameter No.PA04 by turning on X20.
The respond code at instruction code execution is set to D9.
Reads remote input (RX20 to RX5F) of buffer
memory to M200 to M263.
Reads RWr7 and RWr6 of buffer memory to
D1 and D9 when instruction code execution
completion (RX29) turns on.
Writes M100 to M163 to remote output (RY20 to
RY5F) of buffer memory.
Read command
Turns on instruction code execution demand
(RY29).
Turns off instruction code execution demand
(RY29) when instruction code execution
completion (RX29) turns on.
Writes parameter No.PA04 read (H0204) to
RWw6.
Turns on instruction code execution demand
(RY29).
Writes parameter group No. write (H8200) to
RWw6 and parameter group PA (H0000) to
RWw7.
Turns off instruction code execution demand
(RY29).