16. INDEXER POSITIONING OPERATION
(2) Detail list
No. Symbol Name and function
Initial
value
Unit Setting range
PD01 *DIA1 Input signal automatic ON selection 1
Select the input devices to be automatically turned ON.
part is for manufacturer setting. Do not set the value by any means.
0
0
Initial value
BIN HEX
Device name
Forward rotation
stroke end (LSP)
0
0
0
Reverse rotation
stroke end (LSN)
0
BIN 0: Used as external input signal.
BIN 1: Automatic ON
Initial value
BIN HEX
Device name
0
0
0
0
Forced stop (EMG)
00
For example, to turn ON SON, the setting is " 4".
0000h Refer to
name and
function
column.
PD02 For manufacturer setting
Do not change this value by any means.
0000h
PD03 Not used in indexer positioning operation. 0000h
PD04
Do not change the parameter. 0000h
PD05 For manufacturer setting
Do not change this value by any means.
0000h
PD06 Not used in indexer positioning operation. 002Bh
PD07 Do not change the parameter. 000Ah
PD08 000Bh
PD09 0002h
PD10 0003h
PD11 0024h
PD12
0C00h
PD13 For manufacturer setting
Do not change this value by any means.
0000h
PD14 Not used in indexer positioning operation.
Do not change the parameter.
0800h
PD15 For manufacturer setting
Do not change this value by any means.
0000h
PD16 *DIAB Input polarity selection
Used to set the proximity dog input polarity. (Refer to section 5.6.)
0
Proximity dog input polarity
0: OFF indicates detection of the dog
1: ON indicates detection of the dog
00
0000h Refer to
name and
function
column.