B.29 METHUMID Specify Air Humidity
The methumid command allows you to specify air humidity. Humidity specified with the methumid
command does not affect receiver operation. Rather, it allows you to create a record of atmospheric
conditions for post-processing purposes.
The methumid set command specifies air humidity at humid. This command only stores the humidity
value in volatile memory, and does not automatically generate a record. The humidity value can then
be displayed/recorded by requesting the met log.
The methumid clear and the methumid default commands clear the humidity setting.
Syntax
methumid set [humid]
methumid default|clear
Message ID = 163
Table 49: METHUMID Default Configuration
Field Data
Value Used if
Not Specified
Bytes Format Units Offset
1 Header - - - 0
2 Parameter Update, see
Table 34 on Page 107
- 4 Enum none H
3 Humidity 0 4 Float percent H+4
Parameter Power-On Freset Stored in NVM
methumid clear clear NO