DL-V3 User Manual Rev 3 189
Table 83: HyperTerminal Default Parameters
COM1 is used to tunnel to COM3 to gain direct access to the Ethernet.
COM2 is used to issue NovAtel commands to the DL-V3 using HyperTerminal communications
software. The communications parameters should be set to the defaults for DL-V3 COM2. Typically,
9600, 8, N, 1, no parity and local echo on.
D.3.3 DL-V3 Commands
D.3.3.1 Switch to Ethernet Device
Once communication has been established between your laptop serial port (or USB port with a USB-
to-serial port adaptor) and COM2 on the DL-V3, enter the following commands:
• LOG VERSION
see Page 177
Record the OEMV-3 part serial number (PSN) for future use (associated with the Ethernet
Media Access Control (MAC) address).
• APPCONTROL
BLUETOOTH 1 see Pages 85-86
Switch COM3 peripheral to Ethernet. On the front of the DL-V3, the Bluetooth LED no
longer glows blue but instead the Ethernet LED glows orange.
• LOG COMCONFIG
refer to the OEMV Firmware Reference Manual
COMCONFIG shows you the current port settings (the default baud setting for COM3 is
115200). The COM commands below ensure both COM1 and COM3 are set to 9600 baud.
• COM COM1 9600 N 8 1
refer to the OEMV Firmware Reference Manual
• COM COM3 9600 N 8 1
• LOG COMCONFIG
The COMCONFIG command should verify that COM3 is now set to 9600 baud.
Parameter Setting
BAUD 9600
DATA BITS 8
PARITY N
STOP BITS 1
FLOW CONTROL NONE
ASCII SETTINGS Disable echo typed characters locally