4.3.8 Drive unit output signal (DO) forced output
POINT
This function is usable during test operation only.
The output signal can be forced on/off independently of the servo status. This function is used for output
signal wiring check, etc. This operation must be performed in the servo off state (SON
off).
Call the display screen shown after power-on.
Using the "MODE" button, show the diagnostic screen.
Press UP button twice.
Press SET button for more than 2 seconds.
Switch on/off the signal below the lit segment.
Indicates the ON/OFF of the output signal. The correspondences
between segments and signals are as in the external output
signal display.
(Lit: ON, extinguished: OFF)
Press UP button once.
RD is switched on.
(RD -SG conduct.)
Press DOWN button once.
RD is switched off.
Press SET button for more than 2 seconds.
Always lit
@
WNG
BWNG
ALM_
INP
ZSP
TLC
MBR
OP
RD
@
@
@
@