5 - 12
5. PARAMETERS
Class No. Symbol Name and function
Initial
value
Unit
Setting
range
60 LPF Low-pass filter/adaptive vibration suppression control
Used to selection the low-pass filter and adaptive vibration suppression
control. (Refer to Chapter 7.)
0
Low-pass filter selection
0: Valid (Automatic adjustment)
1: Invalid
When you choose "valid",
2 (1 GD2 setting 0.1)
VG2 setting 10
bandwidth filter is set automatically.
Adaptive vibration suppression control selection
Choosing "valid" or "held" in adaptive vibration
suppression control selection makes the machine
resonance control filter 1 (DRU parameter No. 58) invalid.
0: Invalid
1: Valid
Machine resonance frequency is always detected
and the filter is generated in response to resonance to
suppress machine vibration.
2: Held
The characteristics of the filter generated so far are held,
and detection of machine resonance is stopped.
Adaptive vibration suppression control sensitivity selection
Used to set the sensitivity of machine resonance detection.
0: Normal
1: Large sensitivity
[H
z
]
0000
Refer to
Name
and
function
column.
61 GD2B Ratio of load inertia moment to servo motor inertia moment 2
Used to set the ratio of load inertia moment to servo motor inertia moment
when gain changing is valid.
Made valid when auto tuning is invalid.
70
0.1
times
0
to
3000
62 PG2B Position control gain 2 changing ratio
Used to set the ratio of changing the position control gain 2 when gain
changing is valid.
Made valid when auto tuning is invalid.
100 % 10
to
200
63 VG2B Speed control gain 2 changing ratio
Used to set the ratio of changing the speed control gain 2 when gain
changing is valid.
Made valid when auto tuning is invalid.
100 % 10
to
200
64 VICB Speed integral compensation changing ratio
Used to set the ratio of changing the speed integral compensation when
gain changing is valid. Made valid when auto tuning is invalid.
100 % 50
to
1000
Expansion DRU parameters 2
65 *CDP Gain changing selection
Used to select the gain changing condition. (Refer to Section 7.5.)
000
Gain changing selection
Gains are changed in accordance with the settings
of DRU parameters No. 61 to 64 under any of the
following conditions:
0: Invalid
1: Gain changing (CDP ) is ON
2: Command frequency is equal to higher than
DRU parameter No. 66 setting
3: Droop pulse value is equal to higher than
DRU parameter No. 66 setting
4: Servo motor speed is equal to higher than
DRU parameter No. 66 setting
0000
Refer to
Name
and
function
column.