Mitsubishi Electronics MR-J2M-P8A Car Amplifier User Manual


 
5 - 18
5. PARAMETERS
Classifi-
cation
No. Symbol Name and Function
Initial
Value
Unit
Setting
Range
5 *MD3 Analog monitor 3 output
Choose the signal to be output to analog monitor 3.
00
Analog monitor 3 selection
0: Servo motor speed ( 4V/max. Servo motor speed)
1: Torque ( 4V/max. Torque)
2: Servo motor speed ( 4V/max. Servo motor speed)
3: Torque ( 4V/max. Torque)
4: Current command ( 4V/max. Current command)
5: Command pulse frequency ( 4V/500kpps)
6: Droop pulses ( 4V/128pulse)
7: Droop pulses ( 4V/2048pulse)
8: Droop pulses ( 4V/8192pulse)
9: Droop pulses ( 4V/32768pulse)
A: Droop pulses ( 4V/131072pulse)
B: Bus voltage ( 4V/400V)
C: In position ( 4V/ON)
D: Ready ( 4V/ON)
E: Trouble ( 4V/ON)
Slot number of analog monitor 3
Choose the slot number output to analog monitor 3.
Slot number set value. Selecting "0" disables output.
0000 Refer to
name
and
function
column.
6
MO1 Analog monitor 1 offset
Used to set the offset voltage of the analog monitor 1 (MO1).
0mV
999
to
999
7
MO2 Analog monitor 2 offset
Used to set the offset voltage of the analog monitor 2 (MO2).
0mV
999
to
999
8
MO3 Analog monitor 3 offset
Used to set the offset voltage of the analog monitor 3 (MO2).
0mV
999
to
999
Basic IFU parameters
9 *OP2 Function selection 2
Used to select the input signal filter.
Input signal filter
0 : None
1 : 1.777ms
2 : 3.555ms
0
2
00
0200 Refer to
name
and
function
column.