13 - 25
13. COMMUNICATION FUNCTIONS
13.12.7 Test operation mode
(1) Instructions for test operation mode
The test operation mode must be executed in the following procedure. If communication is interrupted
for longer than 0.5s during test operation, the servo amplifier causes the motor to be decelerated to a
stop and servo-locked. To prevent this, continue communication without a break, e.g. monitor the
status display.
(a) Execution of test operation
1) Turn off all external input signals.
2) Disable the external input signals.
Unit
Command Data No. Data
IFU DRU
[9][2] [0][0] 1EA5
3) Choose the test operation mode.
Unit
Command Data No. Transmission data Selection of test operation mode
IFU DRU
[8][B] [0][0] 0000 Test operation mode cancel
[8][B] [0][0] 0001 Jog operation
[8][B] [0][0] 0002 Positioning operation
[8][B] [0][0] 0003 Motor-less operation
[8][B] [0][0] 0004 DO forced output
4) Set the data needed for test operation.
5) Start.
6) Continue communication using the status display or other command.
(b) Termination of test operation
To terminate the test operation mode, complete the corresponding operation and:
1) Clear the test operation acceleration/deceleration time constant.
Unit
Command Data No. Data
IFU DRU
[A][0] [1][2] 1EA5
2) Cancel the test operation mode.
Unit
Command Data No. Data
IFU DRU
[8][B] [0][0] 0000
3) Enable the disabled external input signals.
Unit
Command Data No. Data
IFU DRU
[9][0] [1][0] 1EA5