12 - 25
12. OPTIONS AND AUXILIARY EQUIPMENT
(2) Wires for cables
When fabricating a cable, use the wire models given in the following table or equivalent:
Table 12.2 Wires for option cables
Characteristics of one core
Type Model
Length
[m(ft)]
Core size
[mm
2
]
Number
of Cores
Structure
[Wires/mm]
Conductor
resistance[ /mm]
Insulation coating
ODd[mm] (Note 1)
(Note 3)
Finishing
OD [mm]
Wire model
2 to 10
(6.56 to 32.8)
0.08
12
(6 pairs)
7/0.127 222 0.38 5.6
UL20276 AWG#28
6pair (BLACK)
MR-JCCBL M-L
20
30
(65.6
98.4)
0.3
12
(6 pairs)
12/0.18 62 1.2 8.2
UL20276 AWG#22
6pair (BLACK)
2 5
(6.56
16.4)
0.2
12
(6 pairs)
40/0.08 105 0.88 7.2
(Note 2)
A14B2343 6P
MR-JCCBL M-H
10 to 20
(32.8 to 65.6)
0.2
14
(7 pairs)
40/0.08 105 0.88 8.0
(Note 2)
A14B0238 7P
Encoder cable
MR-JC4CBL
M-H
30 to 50
(98.4 to 164)
0.2
14
(7 pairs)
40/0.08 105 0.88 8.0
(Note 2)
A14B0238 7P
Communication
cable
MR-CPCATCBL3M 3 (9.84) 0.08
6
(3 pairs)
7/0.127 222 0.38 4.6
UL20276 AWG#28
3pair (BLACK)
Bus cable MR-J2HBUS M
0.5 to 5
(1.64 to 16.4)
0.08
20
(10 pairs)
7/0.127 222 0.38 6.1
UL20276 AWG#28
10pair (CREAM)
Battery unit
cable
MR-J2MBATCBL
M
0.3
1
(0.98
3.28)
0.3
2
(1 pairs)
12/0.18 63 1.5 5.1 MVVS IP
0.3mm
2
Note 1. d is as shown below:
d
Conductor
Insulation sheath
2. Purchased from Toa Electric Industry
3. Standard OD. Max. OD is about 10% greater.