5 - 19
5. PARAMETERS
Classifi-
cation
No. Symbol Name and Function
Initial
Value
Unit
Setting
Range
10 *INS Interface unit serial communication
Choose the serial communication station number of the interface
unit.
When making selection, avoid setting the station number used by
any other unit.
00
to
31
11 *SL1 1 slot serial communication station number selection
Choose the station number of the drive unit connected to the first
slot of the base unit.
When making selection, avoid setting the station number used by
any other unit.
10
to
31
12 *SL2 2 slot serial communication station number selection
Choose the station number of the drive unit connected to the second
slot of the base unit.
When making selection, avoid setting the station number used by
any other unit.
20
to
31
13 *SL3 3 slot serial communication station number selection
Choose the station number of the drive unit connected to the third
slot of the base unit.
When making selection, avoid setting the station number used by
any other unit.
30
to
31
14 *SL4 4 slot serial communication station number selection
Choose the station number of the drive unit connected to the fourth
slot of the base unit.
When making selection, avoid setting the station number used by
any other unit.
40
to
31
Basic IFU parameters
15 *SL5 5 slot serial communication station number selection
Choose the station number of the drive unit connected to the fifth
slot of the base unit.
When making selection, avoid setting the station number used by
any other unit.
50
to
31