4 - 12
4. OPERATION
(3) Command system
After selection of preset point tables using the input signals or communication, operation is started by the
forward rotation start (ST1) or reverse rotation start (ST2). Automatic operation has the absolute value
command system, incremental value command system.
(a) Absolute value command system
As position data, set the target address to be reached.
Setting range:
999999 to 999999 [ 10
STM
m] (STM feed length multiplication parameter No.PA05)
Position data setting range
[ 10 m]
999999
999999
STM
(b) Incremental value command system
As position data, set the moving distance from the current address to the target address.
Setting range: 0 to 999999 [
10
STM
m] (STM feed length multiplication parameter No.PA05)
Current address
Target address
Position data |target address - current address|