13 - 22
13. OPTIONS AN
D AUXILIARY EQUIPMENT
(3) Parameter setting
Set parameter No. PA02 according to the option to be used.
Selection of regenerative option
00: Regenerative option is not used
For MR-J3-10T, regenerative resistor is not used.
For MR-J3-20T 40T 60T(4) to 700T(4) built-in regenerative
resistor is used.
Supplied regenerative resistors or regenerative option is used with
the MR-J3-11KT(4) to 22KT(4) servo amplifier.
01: FR-BU2-(H) FR-RC-(H) FR-CV-(H)
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50(Cooling fan is required)
08: MR-RB31
09: MR-RB51(Cooling fan is required)
80: MR-RB1H-4
81: MR-RB3M-4(Cooling fan is required)
82: MR-RB3G-4(Cooling fan is required)
83: MR-RB5G-4(Cooling fan is required)
84: MR-RB34-4(Cooling fan is required)
85: MR-RB54-4(Cooling fan is required)
FA:When regenerative resistors or regenerative option supplied to MR-
J3-11KT(4) to 22KT(4) are cooled by cooling fans to increase
00
Parameter No. PA02
The following are setting values for regenerative resistor and regenerative option which are used with a
servo amplifier of 11k to 22kW.
Regenerative resistor, regenerative option
Setting
value
Standard supplied regenerative resistor 00
Standard supplied regenerative resistor
(with a cooling fan to cool it)
FA
MR-RB5E 00
MR-RB5E (with a cooling fan to cool it) FA
MR-RB9P 00
MR-RB9P (with a cooling fan to cool it) FA
MR-RB9F 00
MR-RB9F (with a cooling fan to cool it) FA
MR-RB6B-4 00
MR-RB6B-4 (with a cooling fan to cool it) FA
MR-RB60-4 00
MR-RB60-4 (with a cooling fan to cool it) FA
MR-RB6K-4 00
MR-RB6K-4 (with a cooling fan to cool it) FA