4 - 31
4. OPERATION
4.6 Manual operation mode
For machine adjustment, home position matching, etc., jog operation or a manual pulse generator may be
used to make a motion to any position.
4.6.1 JOG operation
(1) Setting
Set the input device and parameters as follows according to the purpose of use. In this case, the point table
No. selection 1 to 8 (DI0 to DI7) are invalid.
Item Device/Parameter used Description
Manual operation mode selection Automatic/manual selection (MD0) Turn MD0 OFF.
Servo motor rotation direction Parameter No.PA14 Refer to (2) in this section.
Jog speed Parameter No.PC12 Set the speed of the servo motor.
Acceleration/deceleration time constant Point table No.1
Use the acceleration/deceleration
time constants in point table No.1.
(2) Servo motor rotation direction
Parameter No. PA14 setting
Servo motor rotation direction
Forward rotation start (ST1) ON Reverse rotation start (ST2) ON
0 CCW rotation CW rotation
1 CW rotation CCW rotation
Parameter No.PA14: 0 Parameter No.PA14: 1
CW
ST2: ON
CW
ST1: ON
ST2: ON
CCW
ST1: ON
CCW
(3) Operation
By turning ST1 ON, operation is performed under the conditions of the jog speed set in the parameter and
the acceleration and deceleration time constants in set point table No.1. For the rotation direction, refer to
(2) in this section. By turning ST2 ON, the servo motor rotates in the reverse direction to forward rotation
start (ST1).