Mitsubishi Electronics MR-J3-D01 Car Amplifier User Manual


 
14 - 16
14. COMMUNICATION FUNCTION
(8) Point table/acceleration time constant (Command [C][7])
Command Data No. Description Setting range Frame length
[C][7] [0][1] to [F][F] Acceleration time constant write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.
0 to 20000 8
(9) Point table/deceleration time constant (Command [C][8])
Command Data No. Description Setting range Frame length
[C][8] [0][1] to [F][F] Deceleration time constant write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.
0 to 20000 8
(10) Point table/dwell (Command [C][A])
Command Data No. Description Setting range Frame length
[C][A] [0][1] to [F][F] Dwell write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.
0 to 20000 8
(11) Point table/auxiliary function (Command [C][B])
Command Data No. Description Setting range Frame length
[C][B] [0][1] to [F][F] Auxiliary function write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.
0 to 3 8
(12) Point table/M code (Command [C][2])
Command Data No. Description Setting range Frame length
[C][2] [0][1] to [F][F] M code write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.
00 to 99 8
(13) External input signal disable (Command [9][0])
Command Data No. Description Setting range Frame length
[9][0] [0][0] Turns off the input devices, external analog input signals
and pulse train inputs with the exception of EMG, LSP and
LSN, independently of the external ON/OFF statuses.
1EA5 4
[9][0] [0][3] Disables all output devices (DO). 1EA5 4
[9][0] [1][0] Enables the disabled input devices (DI), external analog
input signals and pulse train inputs with the exception of
EMG, LSP and LSN.
1EA5 4
[9][0] [1][3] Enables the disabled output devices (DO). 1EA5 4