Mitsubishi Electronics MR-J3-D01 Car Amplifier User Manual


 
13 - 77
13. OPTIONS AN
D AUXILIARY EQUIPMENT
(b) Surge suppressor
The recommended surge suppressor for installation to an AC relay, AC valve, AC electromagnetic
brake or the like near the servo amplifier is shown below. Use this product or equivalent.
Surge suppressor
MC
Surge suppressor
Relay
Surge suppressor
This distance should be short
(within 20cm(0.79 in.)).
(Ex.) 972A.2003 50411
(Matsuo Electric Co.,Ltd.
200VAC rating)
Rated
voltage
AC[V]
C [
F] R [ ] Test voltage AC[V]
Outline drawing [Unit: mm]
Blue vinyl cord
Red vinyl cord
Vinyl sheath
200
or more
200
or more
6
31
10 or less 10 or less
48 1.5
15 1
10 3
10 3
4
18 1.5
200 0.5
50
(1W)
Across
T-C 1000(1 to 5s)
Note that a diode should be installed to a DC relay, DC valve or the
like.
Maximum voltage: Not less than 4 times the drive voltage of the
relay or the like
Maximum current: Not less than twice the drive current of the
relay or the like
Diode
RA