Mitsubishi Electronics MR-J3-D01 Car Amplifier User Manual


 
5 - 6
5. PARAMETERS
5.1.7 Feeding function selection
Parameter
Initial
value
Unit Setting range
No. Symbol Name
PA05 *FTY Feeding function selection 0000h Refer to the text.
POINT
This parameter is made valid when power is switched off, then on after
setting, or when the controller reset has been performed.
Select the feed length multiplication and the manual pulse generator input multiplication.
999999 to 9999991000
00
Manual pulse generator multiplication factor
0: 1 time
1: 10 times
2: 100 times
1
2
3
0 999.999 to 999.999 0 to 999.999
Absolute value
command system
Incremental value
command system
Position data input range [mm]
11
10 10
100 100
1000
9999.99 to 9999.99 0 to 9999.99
99999.9 to 99999.9 0 to 99999.9
0 to 999999
Parameter No.PA05
Setting
value
Feed length
multiplication
factor (STM)
[times]
Feed unit
[ m]
5.1.8 Electronic gear
Parameter
Initial
value
Unit Setting range
No. Symbol Name
PA06 *CMX Electronic gear numerator 1 0 to 65535
PA07 *CDV Electronic gear denominator 1 0 to 65535
CAUTION
False setting will result in unexpected fast rotation, causing injury.
POINT
This parameter is made valid when power is switched off, then on after
setting, or when the controller reset has been performed.
The range of the electronic gear setting is
CMX
CDV
1
10
2000
. If you set any
value outside this range, a parameter error (A37) occurs.
Setting "0" in parameter No.PA06 automatically sets the encoder resolution
pulse.